This is the latest recevied telemetry packets stored in our database for station/object KM7EYB-15. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vbatt* | SoC* | Current* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1794913022 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794911215 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794909409 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794907603 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794905796 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794903990 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794902183 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794900378 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794898571 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794896766 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794894959 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794893153 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794891347 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794889543 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794887734 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794885928 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794884122 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794882316 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794880511 | 13.1 V | 94 % | 0 A | 0 | 0 |
| 1794878703 | 13.1 V | 95 % | 0 A | 0 | 0 |
| 1794876897 | 13.1 V | 95 % | 0 A | 0 | 0 |
| 1794875090 | 13.1 V | 95 % | 0 A | 0 | 0 |
| 1794873283 | 13.1 V | 95 % | 0 A | 0 | 0 |
| 1794871477 | 13.1 V | 95 % | 0 A | 0 | 0 |
| 1794869671 | 13.1 V | 95 % | 0 A | 0 | 0 |
*Used Equation Coefficients:
Vbatt: 0, 0.1, 0
SoC: 0, 1, 0
Current: 0, 1, -128
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)