This is the latest recevied telemetry packets stored in our database for station/object N7723V. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Value1* | Value2* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1790561535 | 388 | 633 | 0 | 0 | 0 |
| 1790561475 | 391 | 632 | 0 | 0 | 0 |
| 1790561422 | 374 | 632 | 0 | 0 | 0 |
| 1790561361 | 407 | 631 | 0 | 0 | 0 |
| 1790561301 | 420 | 631 | 0 | 0 | 0 |
| 1790561295 | 406 | 631 | 0 | 0 | 0 |
| 1790561291 | 420 | 631 | 0 | 0 | 0 |
| 1790561285 | 407 | 631 | 0 | 0 | 0 |
| 1790561278 | 408 | 631 | 0 | 0 | 0 |
| 1790561241 | 459 | 631 | 0 | 0 | 0 |
| 1790561182 | 465 | 632 | 0 | 0 | 0 |
| 1790561135 | 475 | 633 | 0 | 0 | 0 |
| 1790561075 | 456 | 634 | 0 | 0 | 0 |
| 1790561015 | 466 | 634 | 0 | 0 | 0 |
| 1790560969 | 459 | 634 | 0 | 0 | 0 |
| 1790560920 | 467 | 635 | 0 | 0 | 0 |
| 1790560881 | 472 | 635 | 0 | 0 | 0 |
| 1790560821 | 455 | 635 | 0 | 0 | 0 |
| 1790560762 | 466 | 635 | 0 | 0 | 0 |
| 1790560702 | 455 | 635 | 0 | 0 | 0 |
| 1790560689 | 455 | 635 | 0 | 0 | 0 |
| 1790560657 | 471 | 635 | 0 | 0 | 0 |
| 1790560598 | 453 | 635 | 0 | 0 | 0 |
| 1790560538 | 471 | 634 | 0 | 0 | 0 |
| 1790560478 | 467 | 634 | 0 | 0 | 0 |
*Used Equation Coefficients:
Value1: 0, 1, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)