This is the latest recevied telemetry packets stored in our database for station/object GOODMN. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Digi1h* | Eff1h* | Value5* |
|---|---|---|---|---|---|
| 1792140387 | 12.72 Volt | 160 Pkt | 50 Pkt | 82 Pcnt | 0 |
| 1792139787 | 12.72 Volt | 150 Pkt | 50 Pkt | 82 Pcnt | 0 |
| 1792139187 | 12.72 Volt | 150 Pkt | 50 Pkt | 80 Pcnt | 0 |
| 1792138587 | 12.72 Volt | 160 Pkt | 50 Pkt | 83 Pcnt | 0 |
| 1792137987 | 12.72 Volt | 160 Pkt | 50 Pkt | 84 Pcnt | 0 |
| 1792137387 | 12.72 Volt | 170 Pkt | 50 Pkt | 85 Pcnt | 0 |
| 1792136787 | 12.72 Volt | 170 Pkt | 60 Pkt | 86 Pcnt | 0 |
| 1792136187 | 12.72 Volt | 170 Pkt | 60 Pkt | 89 Pcnt | 0 |
| 1792135587 | 12.72 Volt | 170 Pkt | 60 Pkt | 88 Pcnt | 0 |
| 1792134987 | 12.72 Volt | 160 Pkt | 50 Pkt | 87 Pcnt | 0 |
| 1792134387 | 12.72 Volt | 160 Pkt | 60 Pkt | 88 Pcnt | 0 |
| 1792133787 | 12.72 Volt | 160 Pkt | 50 Pkt | 89 Pcnt | 0 |
| 1792133187 | 12.72 Volt | 160 Pkt | 50 Pkt | 86 Pcnt | 0 |
| 1792132587 | 12.72 Volt | 170 Pkt | 50 Pkt | 84 Pcnt | 0 |
| 1792131987 | 12.72 Volt | 170 Pkt | 50 Pkt | 86 Pcnt | 0 |
*Used Equation Coefficients:
Vin: 0, 0.079, 0
Rx1h: 0, 10, 0
Digi1h: 0, 10, 0
Eff1h: 0, 1, 0
Value5: 0, 0, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)