This is the latest recevied telemetry packets stored in our database for station/object IR4BA. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx10m* | Dg10m* | Eff1h* | Temp* |
---|---|---|---|---|---|
1719418184 | 13.43 Volt | 72 Pkt | 30 Pkt | 50 Pcnt | 16 C |
1719417885 | 13.58 Volt | 62 Pkt | 22 Pkt | 49 Pcnt | 15.5 C |
1719417884 | 13.58 Volt | 62 Pkt | 22 Pkt | 49 Pcnt | 15.5 C |
1719417584 | 13.5 Volt | 65 Pkt | 22 Pkt | 47 Pcnt | 15.5 C |
1719417285 | 13.58 Volt | 53 Pkt | 19 Pkt | 47 Pcnt | 15.5 C |
1719417284 | 13.58 Volt | 53 Pkt | 19 Pkt | 47 Pcnt | 15.5 C |
1719416984 | 14.1 Volt | 41 Pkt | 19 Pkt | 47 Pcnt | 15.5 C |
1719416685 | 14.1 Volt | 47 Pkt | 24 Pkt | 47 Pcnt | 15.5 C |
1719416684 | 14.1 Volt | 47 Pkt | 24 Pkt | 47 Pcnt | 15.5 C |
1719416384 | 14.1 Volt | 48 Pkt | 25 Pkt | 47 Pcnt | 15.5 C |
1719416085 | 14.1 Volt | 43 Pkt | 11 Pkt | 48 Pcnt | 15.5 C |
1719416084 | 14.1 Volt | 43 Pkt | 11 Pkt | 48 Pcnt | 15.5 C |
1719415784 | 14.1 Volt | 49 Pkt | 13 Pkt | 47 Pcnt | 15.5 C |
1719415485 | 14.1 Volt | 44 Pkt | 11 Pkt | 47 Pcnt | 15.5 C |
1719415484 | 14.1 Volt | 44 Pkt | 11 Pkt | 47 Pcnt | 15.5 C |
1719415184 | 14.1 Volt | 41 Pkt | 13 Pkt | 47 Pcnt | 15.5 C |
1719414885 | 14.1 Volt | 49 Pkt | 17 Pkt | 48 Pcnt | 15.5 C |
1719414884 | 14.1 Volt | 49 Pkt | 17 Pkt | 48 Pcnt | 15.5 C |
1719414584 | 14.03 Volt | 46 Pkt | 14 Pkt | 47 Pcnt | 15.5 C |
1719414285 | 14.1 Volt | 40 Pkt | 13 Pkt | 47 Pcnt | 15.5 C |
1719414284 | 14.1 Volt | 40 Pkt | 13 Pkt | 47 Pcnt | 15.5 C |
1719413984 | 14.1 Volt | 43 Pkt | 12 Pkt | 48 Pcnt | 15.5 C |
1719413685 | 14.1 Volt | 39 Pkt | 13 Pkt | 48 Pcnt | 15.5 C |
1719413684 | 14.1 Volt | 39 Pkt | 13 Pkt | 48 Pcnt | 15.5 C |
1719413384 | 14.1 Volt | 40 Pkt | 17 Pkt | 49 Pcnt | 15.5 C |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx10m: 0, 1, 0
Dg10m: 0, 1, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)