This is the latest recevied telemetry packets stored in our database for station/object IR4BA. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx10m* | Dg10m* | Eff1h* | Temp* |
---|---|---|---|---|---|
1719983966 | 13.28 Volt | 39 Pkt | 13 Pkt | 47 Pcnt | 19.5 C |
1719983667 | 13.8 Volt | 34 Pkt | 12 Pkt | 48 Pcnt | 19.5 C |
1719983666 | 13.8 Volt | 34 Pkt | 12 Pkt | 48 Pcnt | 19.5 C |
1719983366 | 13.73 Volt | 32 Pkt | 14 Pkt | 47 Pcnt | 19.5 C |
1719983067 | 13.8 Volt | 37 Pkt | 14 Pkt | 49 Pcnt | 19.5 C |
1719983066 | 13.8 Volt | 37 Pkt | 14 Pkt | 49 Pcnt | 19.5 C |
1719982766 | 13.8 Volt | 41 Pkt | 11 Pkt | 51 Pcnt | 19.5 C |
1719982467 | 13.8 Volt | 30 Pkt | 10 Pkt | 50 Pcnt | 19.5 C |
1719982466 | 13.8 Volt | 30 Pkt | 10 Pkt | 50 Pcnt | 19.5 C |
1719982166 | 13.8 Volt | 28 Pkt | 9 Pkt | 52 Pcnt | 19.5 C |
1719981867 | 13.73 Volt | 30 Pkt | 6 Pkt | 54 Pcnt | 19.5 C |
1719981866 | 13.73 Volt | 30 Pkt | 6 Pkt | 54 Pcnt | 19.5 C |
1719981566 | 13.8 Volt | 50 Pkt | 14 Pkt | 55 Pcnt | 19.5 C |
1719981267 | 13.8 Volt | 52 Pkt | 15 Pkt | 59 Pcnt | 19.5 C |
1719981266 | 13.8 Volt | 52 Pkt | 15 Pkt | 59 Pcnt | 19.5 C |
1719980966 | 13.73 Volt | 38 Pkt | 9 Pkt | 59 Pcnt | 19.5 C |
1719980667 | 13.8 Volt | 35 Pkt | 11 Pkt | 58 Pcnt | 19.5 C |
1719980666 | 13.8 Volt | 35 Pkt | 11 Pkt | 58 Pcnt | 19.5 C |
1719980366 | 13.8 Volt | 37 Pkt | 11 Pkt | 61 Pcnt | 20 C |
1719980067 | 13.73 Volt | 35 Pkt | 8 Pkt | 62 Pcnt | 20 C |
1719980066 | 13.73 Volt | 35 Pkt | 8 Pkt | 62 Pcnt | 20 C |
1719979766 | 13.73 Volt | 57 Pkt | 20 Pkt | 63 Pcnt | 20 C |
1719979467 | 13.73 Volt | 48 Pkt | 20 Pkt | 63 Pcnt | 20 C |
1719979466 | 13.73 Volt | 48 Pkt | 20 Pkt | 63 Pcnt | 20 C |
1719979166 | 13.73 Volt | 39 Pkt | 13 Pkt | 63 Pcnt | 20 C |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx10m: 0, 1, 0
Dg10m: 0, 1, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)