This is the latest recevied telemetry packets stored in our database for station/object SR4DOS. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx1h* | Dg1h* | Eff1h* | eff* |
---|---|---|---|---|---|
1719646066 | 14.03 Volt | 470 Pkt | 0 Pkt | 54 Pcnt | 55 Pcnt |
1719645766 | 14.03 Volt | 510 Pkt | 0 Pkt | 54 Pcnt | 55 Pcnt |
1719645467 | 14.03 Volt | 540 Pkt | 0 Pkt | 54 Pcnt | 55 Pcnt |
1719645466 | 14.03 Volt | 540 Pkt | 0 Pkt | 54 Pcnt | 55 Pcnt |
1719645166 | 14.03 Volt | 580 Pkt | 0 Pkt | 54 Pcnt | 55 Pcnt |
1719644866 | 14.03 Volt | 640 Pkt | 0 Pkt | 55 Pcnt | 55 Pcnt |
1719644566 | 14.03 Volt | 680 Pkt | 0 Pkt | 55 Pcnt | 55 Pcnt |
1719644266 | 14.03 Volt | 730 Pkt | 0 Pkt | 53 Pcnt | 55 Pcnt |
1719643966 | 14.03 Volt | 760 Pkt | 0 Pkt | 53 Pcnt | 55 Pcnt |
1719643667 | 14.03 Volt | 810 Pkt | 0 Pkt | 52 Pcnt | 55 Pcnt |
1719643666 | 14.03 Volt | 810 Pkt | 0 Pkt | 52 Pcnt | 55 Pcnt |
1719643366 | 14.03 Volt | 860 Pkt | 10 Pkt | 52 Pcnt | 55 Pcnt |
1719643066 | 14.03 Volt | 910 Pkt | 10 Pkt | 53 Pcnt | 55 Pcnt |
1719642766 | 14.03 Volt | 940 Pkt | 10 Pkt | 52 Pcnt | 55 Pcnt |
1719642466 | 14.03 Volt | 970 Pkt | 10 Pkt | 52 Pcnt | 55 Pcnt |
1719642166 | 14.03 Volt | 1010 Pkt | 10 Pkt | 52 Pcnt | 55 Pcnt |
1719641867 | 14.03 Volt | 1040 Pkt | 10 Pkt | 51 Pcnt | 55 Pcnt |
1719641866 | 14.03 Volt | 1040 Pkt | 10 Pkt | 51 Pcnt | 55 Pcnt |
1719641566 | 14.03 Volt | 1070 Pkt | 10 Pkt | 52 Pcnt | 55 Pcnt |
1719641266 | 14.03 Volt | 1070 Pkt | 10 Pkt | 51 Pcnt | 55 Pcnt |
1719640966 | 14.03 Volt | 1090 Pkt | 10 Pkt | 52 Pcnt | 55 Pcnt |
1719640666 | 14.03 Volt | 1110 Pkt | 10 Pkt | 53 Pcnt | 55 Pcnt |
1719640366 | 14.03 Volt | 1140 Pkt | 10 Pkt | 54 Pcnt | 55 Pcnt |
1719640067 | 14.03 Volt | 1170 Pkt | 10 Pkt | 54 Pcnt | 55 Pcnt |
1719640066 | 14.03 Volt | 1170 Pkt | 10 Pkt | 54 Pcnt | 55 Pcnt |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
eff: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)